Re-Revision Total Hip Replacement

71 years old female presented to us with recurrent dislocation of right hip following right Total Hip Replacement for fracture Neck of femur in 2009. Patient underwent closed reduction successfully but again dislocated for which acetabular cup was revised in Oct 2018. Despite of that patient dislocated again.
Management of recurrent dislocation after total hip replacement is challenging due to high incidence of redislocation
We did Re- Revision Total Hip replacement with filling of the acetabulr defect with trabecular metal cup and we used burch Schneider cage and cemented cup. Stem was not revised. Postoperatively patient is comfortable and walking with the help of walker.

re-revision-total-hip-replacement-by-dr-shekhar-agarwal